Upper bound on the per-trial failure rate after a failure-free campaign.

Poisson (rule of three):  p_upper = -ln(1 - C) / n
exact binomial:           p_upper = 1 - (1 - C)^(1/n)

With target_rate, also the clean trials that bound the rate at the target: ceil(ln(1 - C) / ln(1 - target)), and its rule-of-three estimate -ln(1 - C) / target (exact form and target added 2026-10-20).

Methods

Name Description
solve Upper bound on the per-trial failure rate after a failure-free campaign.

solve

solvers.ZeroFailureModel.solve(trials, confidence, target_rate=None)

Upper bound on the per-trial failure rate after a failure-free campaign.

Parameters

Name Type Description Default
trials int Positive number of independent failure-free trials. required
confidence float One-sided confidence level in (0, 1). required
target_rate Optional[float] Optional target per-trial failure probability in (0, 1). None

Returns

Name Type Description
ZeroFailureResult Dimensionless approximate/exact failure bounds and trial counts; optional target counts are None when no target is supplied.

Notes

Equation: For n trials and confidence C, approximate upper failure probability is -ln(1-C)/n; exact upper probability is 1-(1-C)^(1/n). A target p requires ceil(ln(1-C)/ln(1-p)) failure-free trials.

Assumptions: Independent identically distributed Bernoulli trials; approximate rate uses the zero-event Poisson bound.

Excludes: Nonstationarity, correlated failures, and proof of absence of failures.

References

Derivation: For independent Bernoulli trials, the probability of zero failures is (1-p)^n. Invert this probability at tail mass 1-C to obtain the exact one-sided bound. Replacing ln(1-p) by -p yields the Poisson approximation; see mlsysim.physics.robotics.assurance.calc_zero_failure_sample_size.