Sensing error scales: stereo triangulation, lever arms, scan sectors, fog, and expansion (added 2026-10-20).

Each function is one textbook relation with units attached. The solvers in engine/solvers/perception.py compose them for one stated machine and site.

Functions

Name Description
calc_contrast_visibility_range Invert exponential contrast attenuation for a black target.
calc_lever_arm_error Estimate signed lateral error from a small angular error.
calc_scan_sector_angle Compute the full scan angle needed to span a width.
calc_stereo_baseline_bias Propagate a baseline calibration change into depth bias.
calc_stereo_depth_sigma Estimate stereo depth uncertainty from disparity noise.
calc_stereo_range_for_sigma Invert the stereo depth-uncertainty relation.
calc_thermal_expansion Compute a member’s signed linear thermal expansion.

calc_contrast_visibility_range

physics.robotics.sensing.calc_contrast_visibility_range(
    extinction,
    contrast_threshold,
)

Invert exponential contrast attenuation for a black target.

Parameters

Name Type Description Default
extinction Quantity Positive homogeneous extinction coefficient in inverse length. required
contrast_threshold float Detectable contrast fraction in (0, 1). required

Returns

Name Type Description
Quantity Modeled visibility range in meters.

Notes

Equation: range = log(1 / contrast_threshold) / extinction.

Assumptions: Unit initial contrast and homogeneous extinction along the sightline.

Excludes: Sensor-specific detection probability, lighting variation, and safety certification.

Equation: C(d) = C_0 exp(-beta d) => d = ln(1 / epsilon) / beta

Koschmieder’s law for a black target against the horizon sky; with epsilon = 0.05 the range is the meteorological optical range.

Source: Koschmieder (1924); WMO Guide to Instruments and Methods of Observation (WMO-No. 8), Vol. I, Ch. 9 (5 percent contrast threshold).

References

Derivation: Solve C(d) = exp(-beta*d) for d at C = contrast_threshold; the existing Koschmieder/WMO attribution motivates this attenuation model.

Examples

>>> from mlsysim.physics.robotics.sensing import calc_contrast_visibility_range
>>> from mlsysim.core.units import ureg
>>> a = calc_contrast_visibility_range(1 / ureg.meter, 0.1)
>>> b = calc_contrast_visibility_range(2 / ureg.meter, 0.1)
>>> assert a == 2 * b

calc_lever_arm_error

physics.robotics.sensing.calc_lever_arm_error(distance, angle)

Estimate signed lateral error from a small angular error.

Parameters

Name Type Description Default
distance Quantity Nonnegative lever-arm length, in length units. required
angle Quantity Signed angular error convertible to radians; use only small angles. required

Returns

Name Type Description
Quantity Signed lateral displacement in millimeters.

Notes

Equation: delta_y = distance * angle_radians.

Assumptions: Small-angle linearization about the aligned direction.

Excludes: Higher-order trigonometric terms and translational calibration error.

Equation: Delta_y = d theta (small angle; d sin(theta) and d tan(theta) differ from it by under 0.01 percent at one degree)

An attitude, mount, or extrinsic angle error grows with range: the same angle that moves a near point millimeters moves a far one decimeters.

References

Derivation: Linearize sin(theta) around zero, then multiply the angular displacement by the lever arm.

Examples

>>> from mlsysim.physics.robotics.sensing import calc_lever_arm_error
>>> from mlsysim.core.units import ureg
>>> error = calc_lever_arm_error(1 * ureg.meter, 0.01 * ureg.radian)
>>> assert error == 0.01 * ureg.meter

calc_scan_sector_angle

physics.robotics.sensing.calc_scan_sector_angle(width, distance)

Compute the full scan angle needed to span a width.

Parameters

Name Type Description Default
width Quantity Positive transverse width in length units. required
distance Quantity Positive perpendicular distance to the center of that width. required

Returns

Name Type Description
Quantity Full scan angle in degrees.

Notes

Equation: phi = 2 * atan(width / (2 * distance)).

Assumptions: A centered planar width perpendicular to the viewing direction.

Excludes: Lens distortion, occlusion, sampling density, and off-axis coverage.

Equation: phi = 2 atan((w / 2) / d)

References

Derivation: The half-width and distance form a right triangle; double its arctangent half-angle.

Examples

>>> from mlsysim.physics.robotics.sensing import calc_scan_sector_angle
>>> from mlsysim.core.units import ureg
>>> angle = calc_scan_sector_angle(2 * ureg.meter, 1 * ureg.meter)
>>> assert abs(angle.to("degree").magnitude - 90) < 1e-10

calc_stereo_baseline_bias

physics.robotics.sensing.calc_stereo_baseline_bias(
    depth,
    baseline,
    baseline_change,
)

Propagate a baseline calibration change into depth bias.

Parameters

Name Type Description Default
depth Quantity Positive target range in length units. required
baseline Quantity Positive calibrated stereo baseline in length units. required
baseline_change Quantity Nonnegative magnitude of the baseline change in length units. required

Returns

Name Type Description
Quantity Depth-bias magnitude in millimeters.

Notes

Equation: delta_z = z * delta_b / b.

Assumptions: Disparity and focal length remain fixed as the baseline changes.

Excludes: Other intrinsic/extrinsic calibration changes and random disparity noise.

Equation: |dz| = z |db| / b

z = f b / d is linear in b at fixed disparity, so a relative baseline error becomes the same relative depth error.

References

Derivation: The stereo equation z = f*b/d is linear in baseline at fixed f and d.

Examples

>>> from mlsysim.physics.robotics.sensing import calc_stereo_baseline_bias
>>> from mlsysim.core.units import ureg
>>> bias = calc_stereo_baseline_bias(1 * ureg.meter, 0.1 * ureg.meter, 1 * ureg.millimeter)
>>> assert bias == (1 * ureg.meter) * (1 * ureg.millimeter) / (0.1 * ureg.meter)

calc_stereo_depth_sigma

physics.robotics.sensing.calc_stereo_depth_sigma(
    depth,
    focal_length_px,
    baseline,
    disparity_sigma_px,
)

Estimate stereo depth uncertainty from disparity noise.

Parameters

Name Type Description Default
depth Quantity Positive target range in length units. required
focal_length_px float Positive rectified focal length in pixels. required
baseline Quantity Positive separation between camera centers in length units. required
disparity_sigma_px float Positive disparity standard deviation in pixels. required

Returns

Name Type Description
Quantity Depth standard deviation in millimeters.

Notes

Equation: sigma_z = z**2 * sigma_d / (f * b).

Assumptions: Rectified stereo, fixed calibration, and small disparity perturbations.

Excludes: Calibration bias, correlated image errors, occlusions, and a safety bound.

Equation: z = f b / d => sigma_z = z^2 sigma_d / (f b)

First-order propagation of disparity noise through triangulation; the error grows with the square of range.

Source: Hartley and Zisserman, Multiple View Geometry, 2nd ed. (2003), Sec. 12.6; Gallup et al., CVPR 2008, eq. 2.

References

Derivation: Differentiate z = f*b/d and multiply the magnitude of its derivative by disparity standard deviation; the existing Hartley-Zisserman attribution describes the stereo geometry.

Examples

>>> from mlsysim.physics.robotics.sensing import calc_stereo_depth_sigma
>>> from mlsysim.core.units import ureg
>>> near = calc_stereo_depth_sigma(1 * ureg.meter, 100, 0.1 * ureg.meter, 1)
>>> far = calc_stereo_depth_sigma(2 * ureg.meter, 100, 0.1 * ureg.meter, 1)
>>> assert far == near * 4

calc_stereo_range_for_sigma

physics.robotics.sensing.calc_stereo_range_for_sigma(
    depth_sigma,
    focal_length_px,
    baseline,
    disparity_sigma_px,
)

Invert the stereo depth-uncertainty relation.

Parameters

Name Type Description Default
depth_sigma Quantity Positive allowed one-sigma depth error in length units. required
focal_length_px float Positive rectified focal length in pixels. required
baseline Quantity Positive camera baseline in length units. required
disparity_sigma_px float Positive disparity standard deviation in pixels. required

Returns

Name Type Description
Quantity Range in meters where the modeled uncertainty reaches the allowance.

Notes

Equation: z = sqrt(depth_sigma * f * b / sigma_d).

Assumptions: The same rectified, small-noise model as calc_stereo_depth_sigma.

Excludes: A deterministic clearance guarantee, calibration bias, and occlusion.

Equation: z* = sqrt(C f b / sigma_d)

The inverse of calc_stereo_depth_sigma: the range wall beyond which one sigma alone spends a clearance C.

References

Derivation: Rearrange sigma_z = z**2*sigma_d/(f*b) and select the positive square root.

Examples

>>> from mlsysim.physics.robotics.sensing import calc_stereo_range_for_sigma
>>> from mlsysim.core.units import ureg
>>> limit = calc_stereo_range_for_sigma(0.1 * ureg.meter, 100, 0.1 * ureg.meter, 1)
>>> assert limit.to("meter").magnitude == 1

calc_thermal_expansion

physics.robotics.sensing.calc_thermal_expansion(
    coefficient,
    length,
    temperature_rise,
)

Compute a member’s signed linear thermal expansion.

Parameters

Name Type Description Default
coefficient Quantity Linear expansion coefficient in inverse temperature, assumed constant. required
length Quantity Positive reference length in length units. required
temperature_rise Quantity Signed temperature difference, using kelvin or a delta-temperature unit. required

Returns

Name Type Description
Quantity Signed length change in millimeters.

Notes

Equation: delta_L = coefficient * length * temperature_rise.

Assumptions: Uniform temperature change and a constant linear expansion coefficient.

Excludes: Thermal gradients, bending, constraints, and temperature-dependent coefficients.

Equation: dL = alpha L dT

References

Derivation: The linear expansion coefficient is the fractional length change per unit temperature difference.

Examples

>>> from mlsysim.physics.robotics.sensing import calc_thermal_expansion
>>> from mlsysim.core.units import ureg
>>> change = calc_thermal_expansion(1e-5 / ureg.kelvin, 1 * ureg.meter, 10 * ureg.kelvin)
>>> assert change.to("millimeter").magnitude > 0