physics.power
physics.power
Power delivery: load steps on a supply rail and their voltage droop.
Functions
| Name | Description |
|---|---|
| calc_dynamic_power_ratio | Estimate the dynamic-power ratio after clock scaling. |
| calc_inductive_droop | Estimate loop-inductance voltage during a linear current ramp. |
| calc_rail_current_step | Convert a power step into a rail-current step. |
calc_dynamic_power_ratio
physics.power.calc_dynamic_power_ratio(
frequency_ratio,
voltage_tracks_frequency=True,
)Estimate the dynamic-power ratio after clock scaling.
Parameters
| Name | Type | Description | Default |
|---|---|---|---|
| frequency_ratio | float | Positive new frequency divided by reference frequency. | required |
| voltage_tracks_frequency | bool | If True, voltage scales by the same ratio; otherwise voltage stays fixed. | True |
Returns
| Name | Type | Description |
|---|---|---|
| float | Dimensionless new dynamic power divided by reference dynamic power. |
Notes
Equation: P_new/P_old = (V_new/V_old)^2 (f_new/f_old), giving r^3 when voltage tracks frequency and r at fixed voltage. Assumptions: identical switched capacitance and activity factor; voltage proportional to frequency is an optional modeling assumption. Excludes: leakage, clock gating changes, transition energy, and physical voltage-frequency operating limits.
References
Derivation: take the ratio of the capacitive switching-power relation P = activity * capacitance * V^2 * f at two operating points.
Examples
>>> calc_dynamic_power_ratio(1.0)
1.0
>>> calc_dynamic_power_ratio(2.0, voltage_tracks_frequency=False) == 2.0
Truecalc_inductive_droop
physics.power.calc_inductive_droop(inductance, current_step, rise_time)Estimate loop-inductance voltage during a linear current ramp.
Parameters
| Name | Type | Description | Default |
|---|---|---|---|
| inductance | Quantity or float | Loop inductance; bare numbers mean henries; physical loop inductance is nonnegative. | required |
| current_step | Quantity or float | Signed current change; bare numbers mean amperes. | required |
| rise_time | Quantity or float | Positive edge duration; bare numbers mean seconds. | required |
Returns
| Name | Type | Description |
|---|---|---|
| Quantity | Signed inductive voltage in volts; a rising current gives positive droop. |
Notes
Equation: delta_V = L delta_I/delta_t. Assumptions: constant lumped inductance and a linear current ramp. Excludes: resistance, decoupling capacitance, distributed parasitics, and converter response. The edge duration must be positive.
References
Derivation: apply the inductor terminal relation V = L dI/dt to a linear ramp.
Examples
>>> calc_inductive_droop(1e-9, 0, 1e-6).m_as('V')
0.0calc_rail_current_step
physics.power.calc_rail_current_step(power_step, rail_voltage)Convert a power step into a rail-current step.
Parameters
| Name | Type | Description | Default |
|---|---|---|---|
| power_step | Quantity or float | Signed load-power change; bare numbers mean watts. | required |
| rail_voltage | Quantity or float | Positive supply voltage; bare numbers mean volts. | required |
Returns
| Name | Type | Description |
|---|---|---|
| Quantity | Signed current change in amperes. |
Notes
Equation: delta_I = delta_P/V. Assumptions: constant rail voltage during the calculation and power measured at that rail rather than upstream of conversion losses. Excludes: converter efficiency, voltage droop feedback, and transient storage.
References
Derivation: subtract two operating points of P = V I at the same V.
Examples
>>> calc_rail_current_step(0, 12).m_as('A')
0.0