physics.motors
physics.motors
Model electric-motor heat, voltage limits, and geared-joint inertia.
The equations cover winding heat, copper resistance, voltage-limited speed, and the inertia match of a geared joint.
Sources: the first-order lumped thermal model and copper’s linear resistance coefficient are standard (Incropera and DeWitt, Fundamentals of Heat and Mass Transfer, lumped capacitance; NBS Handbook 100, Copper Wire Tables); the inertia match N* = sqrt(J_load / J_rotor) and the brushless terminal equation follow Lynch and Park, Modern Robotics (2017), Sec. 8.9, and Krishnan, Permanent Magnet Synchronous and Brushless DC Motor Drives (CRC Press, 2010).
Functions
| Name | Description |
|---|---|
| calc_contact_force_rate | Calculate contact force buildup against a linear elastic surface. |
| calc_copper_resistance_factor | Calculate winding resistance relative to its reference value. |
| calc_first_order_temperature | Evolve a lumped winding temperature under constant heating. |
| calc_first_order_time_to_temperature | Invert the first-order heating or cooling trajectory. |
| calc_inertia_matched_ratio | Find the ideal gear ratio that maximizes joint acceleration. |
| calc_peak_normalized_response | Evaluate a response normalized to its peak at unit ratio. |
| calc_periodic_burst_peak_rise | Calculate steady-cycle peak temperature rise under periodic heating. |
| calc_voltage_limited_speed | Estimate brushless-motor speed at the available terminal voltage. |
calc_contact_force_rate
physics.motors.calc_contact_force_rate(stiffness, approach_velocity)Calculate contact force buildup against a linear elastic surface.
Parameters
| Name | Type | Description | Default |
|---|---|---|---|
| stiffness | Quantity | Positive contact stiffness, in newton/meter. | required |
| approach_velocity | Quantity | Nonnegative penetration speed, in meter/second. | required |
Returns
| Name | Type | Description |
|---|---|---|
| Quantity | Force increase rate in newton/millisecond. |
Notes
Equation: dF/dt = k v. Assumptions: Hookean contact F = k x and constant positive penetration speed. Excludes: damping, finite-mass impact dynamics, plastic deformation, and force controller response. This rate is not a contact-safety certification.
References
Derivation: differentiate F = k x with constant stiffness and dx/dt = v.
Examples
>>> calc_contact_force_rate(1000 * ureg.N / ureg.m, 0 * ureg.m / ureg.s).m_as('N/ms')
0.0calc_copper_resistance_factor
physics.motors.calc_copper_resistance_factor(
temperature,
alpha,
reference_temperature,
)Calculate winding resistance relative to its reference value.
Parameters
| Name | Type | Description | Default |
|---|---|---|---|
| temperature | Quantity | Winding temperature, convertible to absolute kelvin. | required |
| alpha | Quantity | Linear temperature coefficient, in inverse kelvin. | required |
| reference_temperature | Quantity | Reference temperature of the resistance measurement, convertible to kelvin. | required |
Returns
| Name | Type | Description |
|---|---|---|
| float | Dimensionless resistance ratio R(T)/R(T_0). |
Notes
Equation: R(T)/R(T_0) = 1 + alpha * (T - T_0). Assumptions: alpha is constant over the temperature interval and the reference resistance is positive. Offset temperatures are converted to kelvin first. Excludes: nonlinear resistivity, self-heating feedback, and frequency effects. The caller must keep the linear approximation in its physical regime.
References
Derivation: first-order expansion of resistivity about the reference temperature, with alpha = (1/R_0) dR/dT at that temperature.
Examples
>>> calc_copper_resistance_factor(300 * ureg.K, 0.004 / ureg.K, 300 * ureg.K)
1.0calc_first_order_temperature
physics.motors.calc_first_order_temperature(
elapsed,
start,
asymptote,
time_constant,
)Evolve a lumped winding temperature under constant heating.
Parameters
| Name | Type | Description | Default |
|---|---|---|---|
| elapsed | Quantity | Elapsed time, nonnegative, in seconds or compatible units. | required |
| start | Quantity | Initial absolute temperature, convertible to kelvin. | required |
| asymptote | Quantity | Constant equilibrium temperature, convertible to kelvin. | required |
| time_constant | Quantity | Positive thermal time constant, in seconds or compatible units. | required |
Returns
| Name | Type | Description |
|---|---|---|
| Quantity | Absolute temperature in kelvin. |
Notes
Equation: T(t) = T_inf - (T_inf - T_0) exp(-t/tau). Assumptions: one uniform thermal state, constant thermal resistance and capacitance, and a constant heat input during the interval. Excludes: spatial gradients, changing cooling conditions, and temperature-dependent losses. Valid time and time-constant ranges are caller obligations.
References
Derivation: solve the lumped heat balance dT/dt = (T_inf - T)/tau with initial condition T(0) = T_0.
Examples
>>> calc_first_order_temperature(0 * ureg.s, 300 * ureg.K, 350 * ureg.K, 10 * ureg.s) == 300 * ureg.K
Truecalc_first_order_time_to_temperature
physics.motors.calc_first_order_time_to_temperature(
start,
target,
asymptote,
time_constant,
)Invert the first-order heating or cooling trajectory.
Parameters
| Name | Type | Description | Default |
|---|---|---|---|
| start | Quantity | Initial absolute temperature, convertible to kelvin. | required |
| target | Quantity | Target temperature between the initial state and asymptote; convertible to kelvin. | required |
| asymptote | Quantity | Constant equilibrium temperature, convertible to kelvin. | required |
| time_constant | Quantity | Positive thermal time constant, in seconds or compatible units. | required |
Returns
| Name | Type | Description |
|---|---|---|
| Quantity or None | Time in seconds, or None for the unreachable heating branch. |
Notes
Equation: t = tau * ln((T_inf - T_0)/(T_inf - T_target)); the cooling branch uses the equivalent ratio (T_0 - T_inf)/(T_target - T_inf). Assumptions: constant forcing, a positive time constant, and a target on the trajectory between start and equilibrium. Cooling requires a target above the asymptote; passing the asymptote exactly can divide by zero. Excludes: varying heat input and validation of every out-of-regime temperature ordering. None is not a general reachability certificate for arbitrary inputs.
References
Derivation: rearrange the exponential solution of :func:calc_first_order_temperature and take its natural logarithm.
Examples
>>> calc_first_order_time_to_temperature(300 * ureg.K, 300 * ureg.K, 350 * ureg.K, 10 * ureg.s).m_as('s')
0.0calc_inertia_matched_ratio
physics.motors.calc_inertia_matched_ratio(load_inertia, rotor_inertia)Find the ideal gear ratio that maximizes joint acceleration.
Parameters
| Name | Type | Description | Default |
|---|---|---|---|
| load_inertia | Quantity | Positive load inertia at the output shaft, in kilogram meter squared. | required |
| rotor_inertia | Quantity | Positive rotor inertia at the motor shaft, in kilogram meter squared. | required |
Returns
| Name | Type | Description |
|---|---|---|
| float | Dimensionless ideal reduction ratio; no minimum gear ratio is imposed. |
Notes
Equation: N_star = sqrt(J_load/J_rotor). Assumptions: constant motor torque and an ideal lossless transmission, with acceleration proportional to N/(J_load + N^2 J_rotor). Excludes: gear inertia, friction, motor speed limits, efficiency, and discrete available gear ratios.
References
Derivation: differentiate N/(J_load + N^2 J_rotor) with respect to N; the stationary point satisfies N^2 J_rotor = J_load.
Examples
>>> calc_inertia_matched_ratio(1 * ureg.kg * ureg.m**2, 1 * ureg.kg * ureg.m**2)
1.0calc_peak_normalized_response
physics.motors.calc_peak_normalized_response(ratio)Evaluate a response normalized to its peak at unit ratio.
Parameters
| Name | Type | Description | Default |
|---|---|---|---|
| ratio | float | Dimensionless operating ratio x, normally nonnegative; e.g. gear ratio divided by its optimum. | required |
Returns
| Name | Type | Description |
|---|---|---|
| float | Dimensionless relative response; signed inputs produce signed outputs. |
Notes
Equation: f(x) = 2x/(1 + x^2). Assumptions: the mechanism has the same linear-over-quadratic response shape; gear acceleration and ideal phase-short braking are possible applications. Excludes: mechanism-specific limits and parameter identification. This helper does not establish that a particular motor follows the assumed curve.
References
Derivation: normalize x/(1 + x^2) by its value at x = 1; the denominator stays positive for finite real x.
Examples
>>> calc_peak_normalized_response(1.0)
1.0calc_periodic_burst_peak_rise
physics.motors.calc_periodic_burst_peak_rise(
power,
thermal_resistance,
on_time,
period,
time_constant,
)Calculate steady-cycle peak temperature rise under periodic heating.
Parameters
| Name | Type | Description | Default |
|---|---|---|---|
| power | Quantity | Nonnegative heat dissipation during the on interval, in watts. | required |
| thermal_resistance | Quantity | Positive thermal resistance to ambient, in kelvin/watt. | required |
| on_time | Quantity | On duration, from zero to period, in seconds. | required |
| period | Quantity | Positive cycle duration, in seconds. | required |
| time_constant | Quantity | Positive lumped thermal time constant, in seconds. | required |
Returns
| Name | Type | Description |
|---|---|---|
| Quantity | Peak rise above ambient in kelvin after many identical cycles. |
Notes
Equation: delta_T_peak = P theta * (1 - exp(-t_on/tau)) / (1 - exp(-period/tau)). Assumptions: periodic square-wave heat input, zero dissipation in the off interval, and constant thermal properties; input ranges are caller obligations. Excludes: transient startup cycles, changing ambient temperature, and separate thermal states for windings, housing, and coolant.
References
Derivation: equate the temperature at the start of successive heating and cooling cycles using the first-order exponential solution.
Examples
>>> rise = calc_periodic_burst_peak_rise(10 * ureg.W, 2 * ureg.K / ureg.W, 5 * ureg.s, 5 * ureg.s, 10 * ureg.s)
>>> round(rise.m_as('K'), 8) == (10 * ureg.W * 2 * ureg.K / ureg.W).m_as('K')
Truecalc_voltage_limited_speed
physics.motors.calc_voltage_limited_speed(
torque,
torque_constant,
terminal_resistance,
supply_voltage,
no_load_speed,
)Estimate brushless-motor speed at the available terminal voltage.
Parameters
| Name | Type | Description | Default |
|---|---|---|---|
| torque | Quantity | Requested nonnegative output torque, in newton meters. | required |
| torque_constant | Quantity | Positive torque per amplitude-invariant phase current, in newton meters/ampere. | required |
| terminal_resistance | Quantity | Nonnegative line-to-line winding resistance, in ohms. | required |
| supply_voltage | Quantity | Positive DC supply voltage, in volts. | required |
| no_load_speed | Quantity | Positive measured no-load angular speed at the supply voltage, in rpm or compatible units. | required |
Returns
| Name | Type | Description |
|---|---|---|
| Quantity | Voltage-limited speed in revolutions/minute; can be negative if the resistive drop exceeds supply. |
Notes
Equation: K_e,LL = V/omega_0 and omega = [V - (sqrt(3)/2) R_TT torque/K_t] / K_e,LL. Assumptions: amplitude-invariant sinusoidal phase current and a constant motor resistance; no-load speed supplies the line-to-line back-EMF coefficient. Excludes: inductive transients, inverter modulation limits, and saturation. A negative result indicates an infeasible requested operating point; it is not clipped into a feasible motor speed.
References
Derivation: substitute phase current i = torque/K_t into the steady motor terminal balance V = K_e,LL omega + (sqrt(3)/2) R_TT i. The current convention must match the supplied torque constant.
Examples
>>> speed = calc_voltage_limited_speed(0 * ureg.N * ureg.m, 1 * ureg.N * ureg.m / ureg.A, 1 * ureg.ohm, 24 * ureg.V, 100 * ureg.rpm)
>>> round(speed.m_as('rpm'), 8) == 100
True